Lessons from the DaVita Healthcare Ransomware Attack
The DaVita ransomware attack is one of the most impactful recent healthcare breaches. Learn what happened and what could have been done to limit the impact.
Proof your safeguards protect ePHI under real attack, done by hand by a senior engineer. You can tell when it’s real. So can OCR.
EHR platforms, patient portals, FHIR and HL7 interfaces, billing systems, and the remote access your clinicians use, taken from your own risk analysis.
Every finding names the Security Rule standard it bears on, so your privacy and security officers can file it straight into the risk analysis.
Business associates have been directly liable under the Security Rule since 2013. We test vendors’ systems in scope with their authorization, and test yours if you are one.
| Security Rule standard | What we test | What the report gives you |
|---|---|---|
| 164.308(a)(1)(ii)(A) Risk analysis | Every system in your ePHI inventory, plus the ones missing from it that we find | Real exposures to replace estimated likelihoods, and assets your inventory missed |
| 164.308(a)(1)(ii)(B) Risk management | Exploitability of each finding, chained where an attacker would chain it | Ranked fixes, then a retest that documents each one closed |
| 164.308(a)(5) Security awareness | Phishing and pretext calls against staff, when in scope | Who clicked, who reported, and how long until anyone did |
| 164.308(a)(8) Evaluation | Your safeguards as configured today, after your last system change | A dated, independent evaluation, repeated on whatever cadence you choose |
| 164.312(a)(1) Access control | Privilege escalation, broken authorization in portals and APIs, shared accounts | Each path from a low-privilege foothold to ePHI, step by step |
| 164.312(b) Audit controls | Whether your logging and monitoring noticed us at all | What fired, what did not, and when |
| 164.312(d) Authentication | MFA gaps, password policy, legacy protocols, session handling | Accounts we took over and how |
| 164.312(e)(1) Transmission security | TLS configuration, cleartext protocols, interface traffic between systems | Where ePHI crosses the network unprotected |
Infusion pumps, imaging workstations, and building systems share networks with the EHR. A scope that excludes them excludes the easiest way in.
Ransomware crews get inside with a stolen or phished password, then move. An external-only test says nothing about what happens next, which is the part that took DaVita and Change Healthcare offline.
A CVE list goes in a folder and the risk analysis keeps its old estimates. We write findings in the risk analysis’s terms so they replace the guesses.
OCR asks what you did about known risks. A retest that documents each fix closed is the answer. Every Raxis engagement includes one.
Most covered entities test once a year and after any significant change to systems that touch ePHI, such as a new EHR module or a cloud migration.
A new patient portal, a merger, a new telehealth vendor. Each one changes your risk analysis, so each one deserves a test.
Raxis Attack tests all year with findings live in Raxis One, so your evaluation is never older than your last release.
Evidence gathered after a breach notice reads as a reaction. Evidence from the prior twelve months reads as practice.
Written by the Raxis engineers who run these tests, from real engagements and research.
The DaVita ransomware attack is one of the most impactful recent healthcare breaches. Learn what happened and what could have been done to limit the impact.
Tim Semchenko discusses documenting acceptance of risks and implementing compensating controls as options when pentest findings cannot be fixed immediately.
Healthcare security may start with HIPAA regulations, but, in the end, it all comes down to protecting patients and the healthcare workers.
Not by name, as of the current Security Rule. It requires a risk analysis under 164.308(a)(1)(ii)(A) and periodic evaluation under 164.308(a)(8), and a penetration test is the most direct evidence for both. In January 2025, HHS proposed requiring a penetration test at least every twelve months, which shows where expectations are heading.
Business associates have been directly liable for Security Rule compliance since the 2013 Omnibus Rule, so the same risk analysis and evaluation duties apply. Many covered entities also ask their business associates for a recent pentest report during vendor review.
Usually, yes, at least the network around them. Clinical devices often run old operating systems and share networks with systems that hold ePHI. We agree with your clinical engineering team on what is safe to touch, and test segmentation around devices that must not be disturbed.
It can help. Under a 2021 amendment to the HITECH Act, OCR must consider whether recognized security practices were in place for the prior twelve months when setting penalties. Documented testing with verified fixes is evidence those practices were operating. It is not a guarantee of any outcome.
It should not. We agree on rules of engagement, testing windows, and systems that are off limits before we start, and we stop and call you if anything behaves unexpectedly. Clinical systems are tested with the care their uptime demands.
At least once a year and after significant changes to systems that touch ePHI. Organizations that change often use Raxis Attack for continuous testing, so the evaluation stays current between annual reviews.